top of page
ReconPillar_LOGOS_PODS_2026-09.png
Screenshot 2026-11-16 at 10.14_edited.png

DATA SHEET

Pillar Pod Wireless Jobsite Sensor Data Sheet

Explore Pillar Pod specifications for seven built-in sensors that monitor temperature, humidity, carbon monoxide, light, particulates, noise, and pressure.

Back to Resource Library
pillar-pod-graphic-transparent.png

What Are Pillar Pods?


Pillar Pods are battery-powered wireless environmental monitors developed by Pillar Technologies and offered as part of Recon Dynamics' Recon Pillar jobsite monitoring solution. Each Pod combines seven listed sensor categories to collect information about ambient conditions that may affect construction materials, workmanship and environmental oversight. The monitoring platform supports automatic cloud data transfer, remote review and configurable alerts, giving teams ongoing environmental records instead of relying exclusively on occasional observations.


What Seven Conditions Do Pillar Pods Measure?


The datasheet identifies temperature, relative humidity, carbon monoxide, ambient light, particulate matter, barometric pressure and noise incidents. Dew point or mold-favorable conditions may be calculated or inferred from applicable readings, but they are not additional physical built-in sensors specified in this sheet.


1. Temperature Monitoring


The stated measurement accuracy is ±1.8°F with 0.018°F resolution. The device's operating temperature range is −4°F to +158°F (−20°C to +70°C). Temperature records help site teams observe freeze-risk periods, weather changes and installation conditions for temperature-sensitive products.


2. Relative Humidity Monitoring


Relative humidity is expressed as % RH. The listed accuracy is ±3% RH, hysteresis ±1.5% RH and resolution 0.008% RH, under specified conditions of 20–80% RH at 77°F. Combining temperature and humidity histories can help investigate condensation and conditions favorable to mold growth; it does not detect mold itself.


3. Carbon Monoxide Monitoring


The datasheet explicitly marks the CO sensor as under testing. It lists an output in parts per million, a 0–10,000 ppm range, repeatability better than ±5%, a 60-second response time and 120-second recovery time. Its conditions are 10–95% RH and 14°F to 122°F; timing values relate to 90% response or baseline recovery. This unverified sensor information is not a certified gas alarm or substitute for workplace safety monitoring.


4. Particulate Matter and Dust Monitoring


The source identifies PM2.5, a listed particle-size span of 0.8–100 µm, concentration output in µg/m³, range of 17–300 µg/m³ and a 17.5 µg/m³ minimum baseline sensitivity. The document's particle-size description should not be confused with the formal aerodynamic diameter definition of PM2.5. Observations may support dust-control trends, but the sheet does not document a regulatory reference method.


5. Ambient Light Monitoring


Light measurement is expressed in foot-candles (fc). The stated spectral band is 300–1,000 nm, measurement range is 0–6,210 fc and resolution is 0.0007 fc. Lighting observations may help characterize working conditions or site activity patterns.


6. Barometric Pressure Monitoring


Pressure output is stated in inches of water column (in. wc). Absolute accuracy is ±0.24 in. wc, relative accuracy ±0.12 in. wc and resolution 0.00073 in. wc. The sheet describes barometric pressure, not a calibrated room-to-room differential-pressure instrument.


7. Noise Incident Monitoring


The source states incident detection for noise occurrences over “−85 dBA.” That unusual printed threshold should be confirmed with the manufacturer before publication as a numeric operating limit. The sheet does not establish calibrated occupational noise exposure monitoring.


Wireless Radio and Data Transmission

  • Standard: 915 MHz ISM.

  • Receiver sensitivity: −140 dBm.

  • Transmitter output: 4 dBm+.

  • Standard transmission interval: 20 seconds.

  • Listed transmission count: 500,000+.


The radio transmission interval is distinct from a cloud sampling, dashboard refresh or reporting schedule. Site network configuration affects when data becomes available remotely.


Dimensions, Environmental Rating and Battery

  • Dimensions: 6.75 × 5.25 × 2.8 inches (171 × 133 × 71 mm).

  • Weight: 24 oz (approximately 680.4 g).

  • Environmental rating: IP20.

  • Operating temperature: −4°F to +158°F (−20°C to +70°C).

  • Battery: non-rechargeable lithium thionyl chloride, listed 18-month life.


IP20 offers limited ingress protection and does not indicate a waterproof enclosure. Placement should account for water exposure and site conditions.


How Contractors Use Pillar Pods


Applications include documenting ambient temperature and humidity during construction, monitoring particulate trends near renovation barriers, reviewing changes in light and noise activity, and using configured alerts to investigate deviations from project-selected limits. Historical records can support quality discussions and risk reviews, but a Pod reading is a measurement at a particular location and time, not a guarantee of full-site conditions.


Frequently Asked Questions


How many integrated sensors are specified?


Seven sensor categories are listed in the datasheet.


Does a Pod directly detect mold or a water leak?


No. Mold-related conditions are inferred from environmental information; water-contact detection is a separate function available through products such as Leak Pucks.


Are Pillar Pods certified safety devices?


No. The source explicitly states, “This is not a safety device.”

bottom of page